Make Chamber Reservation

 

 

 

 

 

 

 

 

 

 

Enclosed by an external metallic shielding to provide isolation from the outside environment. Interior lined with radio frequency/microwave absorbers and ferrite tiles to minimize unwanted multiple internal signal reflections inside the chamber to emulate an isolated, “free space” environment for radiation testing.

 

 

 

 

 

 

 

 

 

 

Specifications:

  • RF Shielding
    • Magnetic field: 20 dB @ 1 kHz, 50 dB @ 10 kHz, 100 dB @ 150 kHz
    • Electric field: 100 dB from 150 kHz to 50 MHz
    • Plane wave: 100 dB from 50 MHz to 1 GHz
    • Microwave: 100 dB @ 10 GHz
  • Absorber
    • Power handling: 775 W/m2
    • Reflection: <-15 dB from 30 MHz to 18 GHz
  • Site-VSWR
    • From 1 GHz to 18 GHz in accordance with CISPR 16-1-4 Ver. 3.0 at 3m
  • Field Uniformity
    • According to IEC-61000-4-3; 50 MHz to 6 GHz at 3m to 10V/m
  • Free-space Normalized Site Attenuation
    • From 30 MHz to 1 GHz in accordance with CISPR 16-1-4 Ver. 3.0 at 3m
  • CTIA Ripple Testing
    • In accordance with CTIA V 3.0, 700 MHz to 6 GHz