Enclosed by an external metallic shielding to provide isolation from the outside environment. Interior lined with radio frequency/microwave absorbers and ferrite tiles to minimize unwanted multiple internal signal reflections inside the chamber to emulate an isolated, “free space” environment for radiation testing.
Specifications:
- RF Shielding
- Magnetic field: 20 dB @ 1 kHz, 50 dB @ 10 kHz, 100 dB @ 150 kHz
- Electric field: 100 dB from 150 kHz to 50 MHz
- Plane wave: 100 dB from 50 MHz to 1 GHz
- Microwave: 100 dB @ 10 GHz
- Absorber
- Power handling: 775 W/m2
- Reflection: <-15 dB from 30 MHz to 18 GHz
- Site-VSWR
- From 1 GHz to 18 GHz in accordance with CISPR 16-1-4 Ver. 3.0 at 3m
- Field Uniformity
- According to IEC-61000-4-3; 50 MHz to 6 GHz at 3m to 10V/m
- Free-space Normalized Site Attenuation
- From 30 MHz to 1 GHz in accordance with CISPR 16-1-4 Ver. 3.0 at 3m
- CTIA Ripple Testing
- In accordance with CTIA V 3.0, 700 MHz to 6 GHz